Certified under CE, UL, CB, and GB/T standards. Our high-power AC and micro-DC systems ensure grid compatibility, robust functional safety (ISO 26262), and modular interoperability via OCPP 1.6J/2.0.1.
As electric vehicle adoption surges past tipping points across the European Union, North America, and APAC, Level 2 alternating current (AC) infrastructure remains the bedrock of urban grid-friendly decarbonization. Delivering from 3.5 kW single-phase to 22 kW / 44 kW three-phase charging profiles, L2 EV chargers optimize dwelling time efficiency while mitigating steep localized transformer loads.
Equipped with industrial grade relay arrays, galvanic isolation, and Type A + DC 6mA residual current monitoring (RCD). Engineered to maintain peak continuous amperage at 40°C to +55°C without thermal derating.
Simultaneous compliance support for SAE J1772 (Type 1), IEC 62196-2 (Type 2), GB/T 20234, and native compatibility with Tesla/NACS protocol lines, facilitating frictionless international deployment.
Native dynamic load balancing (DLB), remote over-the-air (OTA) diagnostic patching, automated billing clearinghouse interfacing, and smart charge schedule orchestration under modern utility time-of-use (TOU) tariffs.
Understanding local electrical distribution topologies (Split-phase 120V/240V in North America vs. 3-Phase 230V/400V TN-C-S in Europe) is critical for commercial EVSE scaling. Below is our engineering synthesis for Level 2 OEM buyers:
| Target Region | Coupler Interface | Nominal AC Input | Max Current / Power | Safety Compliance | Smart Protocol |
|---|---|---|---|---|---|
| North America | SAE J1772 / NACS | 208V / 240V Split-Phase | 32A–48A (7.7kW–11.5kW) | UL 2594, UL 2231, NEC 625 | OCPP 1.6J / ISO 15118 |
| Europe & UK | IEC 62196-2 Type 2 | 230V 1P / 400V 3P | 16A–32A (11kW–22kW) | EN IEC 61851-1, CE-LVD, RED | OCPP 2.0.1 DLB Ready |
| APAC / China | GB/T 20234.2 | 220V 1P / 380V 3P | 32A–63A (7kW–44kW Dual) | CQC, GB/T 18487.1 | Cloud API / 4G / RS485 |
| Emerging LatAm / MEA | Multi-Inlet Type 2 / GBT | 220V–415V Universal | 16A–32A (7.4kW–22kW) | IEC Standardized CB Scheme | RFID / POS Terminal / BLE |
Utilizing local mesh networking and Master-Slave DLB architecture, up to 32 chargers communicate locally to throttle charging rates against the building's main breaker threshold, preventing expensive grid capacity upgrades.
Designed for municipal transit, logistics vans, and taxi dispatch yards where 6-8 hour dwelling windows allow high-reliability AC Level 2 charging to cycle packs gently, extending EV battery life while slashing demand charges.
Monetize parking spaces with customizable payment modules (Credit Card POS, App Scan, RFID), secondary high-brightness LCD media screens, and integrated enterprise white-label app experiences.
Detailed engineering answers designed for charging point operators (CPOs), fleet directors, electrical contractors, and distribution partners evaluating Level 2 supply chain capabilities.
Our Level 2 charging units feature an automotive-grade internal architecture housed in UV-stabilized, impact-resistant polycarbonate and flame-retardant enclosures (UL94 V-0, IK10 rated). Heat-generating power elements—including internal switching power modules, smart metering ICs, and heavy-duty contactors—are placed on isolated thermal dissipation zones with heat sinks. Chargers run full rated amperage (e.g. 32A/48A) across -30°C to +50°C without premature thermal throttling.
Yes. As a primary manufacturer based in Kunshan, China, we operate proprietary sheet metal stamping, injection tooling, and SMT lines. We support customized external industrial design, custom LED light guide styling, pantone-matched powder coats, laser-etched brand badges, custom LCD boot screens, and pre-configured OCPP endpoint endpoints connecting directly to your back-office cloud.
Our boards integrate comprehensive 12-point protection: Over-voltage protection (OVP), Under-voltage protection (UVP), Over-current protection (OCP), Short-circuit protection (SCP), Earth leakage protection (Type A 30mA AC + 6mA DC smooth residual current sensor conforming to IEC 62955), Over-temperature protection (OTP), Lightning/Surge suppression (Type II SPD), Ground fault monitoring, Relay weld detection, and Emergency Stop interlocking.
Our smart Level 2 systems communicate via RS485 (Modbus RTU) or local Wi-Fi/Ethernet with energy meters installed at the grid connection point. When total household or facility consumption spikes, the charger automatically reduces its output amperage. When combined with our 100kWh/200kWh Energy Storage Charging Piles and rooftop solar, the system shifts charging sessions to maximize solar self-consumption and peak-shaving benefits.
For standard configurations with basic branding (silk screen logo and UI asset replacement), our MOQ begins at 50 units with lead times between 2 to 3 weeks. Full custom tooling for novel outer casings or custom PCB board redesigns typically spans 6 to 8 weeks for pilot sample delivery, backed by comprehensive ISO 9001 quality documentation, test bench reports, and factory acceptance test (FAT) logging.
Complementing our Level 2 AC product line, Suzhou HizonSun manufactures high-power DC fast-charging solutions and energy-storage integrated charging systems designed for severe commercial conditions.