Enterprise-Grade EV Hardware Engineering

ODM Electric Vehicle Charging Infrastructure Factories & Factory

Vertical industrial manufacturing, silicon carbide (SiC) topologies, and end-to-end turnkey hardware/firmware execution for global CPOs, highway authorities, and enterprise fleets.

Hardware Catalog Part 1

High-Power DC Fast Chargers & Split Systems

Direct manufacturer deployment of multi-standard commercial charging stations compliant with CE, GB/T, UL, and IEC protocols.

Split Type DC Fast EV Charging Station 360KW-720KW

ODM Factory Split Type DC Fast EV Charging Station 360KW-720KW | 8-12 Guns

Configure Station
OEM 60KW-360KW Dual Gun DC EV Charger

OEM 60KW-360KW Dual Gun DC EV Charger | Octagonal Fast Charging Station

Configure Station
China CE Certified China DC Charging Pile 60-360KW

CE Certified DC Charging Pile 60-360KW | Turnkey Fast Charger Systems

Configure Station
OEM 20KW 30KW 40KW DC EV Charger

OEM 20KW/30KW/40KW DC EV Charger | Low-Profile Wallbox & Pedestal

Configure Station
OEM 60KW-240KW DC Fast EV Charging Station with 32 Screen

OEM 60KW-240KW DC Fast EV Charging Station with 32” Advertising Display & POS

Configure Station
China 60KW-400KW Integrated DC EV Charging Pile

60KW-400KW Integrated DC EV Charging Pile | High-Reliability Outdoor Unit

Configure Station
China 60KW-360KW Dual Gun DC EV Charger

Dual Gun DC EV Charger 60-360KW | Octagonal Architectural Heavy-Duty Shell

Configure Station
OEM 32-Inch DC Charging Pile for EVs 60-240kW

32-Inch Commercial DC Charger 60-240kW | Integrated Media & Fleet Dispenser

Configure Station
Procurement Intelligence & Analysis

Enterprise EV Charging Procurement Requirements

Industrial perspectives on systemic supply chain integration, total cost of ownership (TCO) matrices, and multi-regional electrical compatibility standards.

Grid Interconnection & Peak Shaving

Global utility providers demand automated load limitation controls to avoid local substation infrastructure collapse. Industrial procurement focuses on hardware-level active demand control and harmonic distortion suppression.

  • Dynamic Phase Load Balancing across high-power dispensers
  • Total Harmonic Distortion (THDi) regulated below 5% at full capacity
  • Bidirectional power-factor optimization reaching ≥ 0.99

Mean Time Between Failures (MTBF)

CPOs lose up to 34% of expected annual operating margins when maintenance calls occur frequently. Factory validation requires robust heat management, moisture exclusion, and power sub-assembly modularity.

  • Independent potting and isolated air ducting for conversion units
  • Hot-swappable 20kW, 30kW, and 40kW AC/DC rectification racks
  • Real-time thermistor telemetry on CCS2, CCS1, and GB/T contact pins

Cryptographic Cloud Interoperability

Security flaws at the charge point leave fleet systems vulnerable. ODM manufacturing must maintain hardware security elements (HSM) alongside strict software copyright validation for OCPP stacks.

  • Native support for OCPP 1.6J and OCPP 2.0.1 with TLS 1.3 security
  • ISO 15118-2 and ISO 15118-20 Plug & Charge enablement
  • Direct hardware integration for payment terminals (POS, RFID, NFC)
10,000 m²
Production Footprint
500,000+
Annual Unit Output
50+
IP & Software Patents
40+
Export Destinies
Application Engineering

Macro Charging Infrastructures by Deployment Scale

Engineered site configurations tailored for long dwell-time destinations, commercial transit hubs, logistics centers, and areas with electrical utility constraints.

Fleet Depot Hubs

High-density electric bus and freight depots require centralized power cabinets with distributed satellite dispensers. Split systems dynamically assign power matrix paths based on vehicle battery capacity.

  • Scalable 360kW to 720kW centralized racks
  • Simultaneous charging for up to 12 parking spots
  • Liquid-cooled cable options handling continuous 500A

Commercial Advertising Sites

Transforming urban parking garages and shopping centers into ad-supported revenue assets. Fast charging infrastructure with built-in high-brightness digital signage displays.

  • 32-inch high-nit outdoor-rated screens
  • Dual CCS2 / GB/T connectors running 60kW to 240kW
  • Independent split-billing CMS integration

Battery Buffered & Microgrid

Designed for locations where the local electrical grid cannot supply 200kW+ directly. High-capacity Lithium Iron Phosphate (LFP) energy storage units manage high demand and connect with solar arrays.

  • Integrated 100kWh & 200kWh battery units
  • Native DC-coupled photovoltaic (PV) solar integration
  • Islanding features for emergency back-up power

Workplace & Destination AC

For vehicles parked for several hours, such as at corporate offices, multi-family housing, and hospitality venues. Reliable AC distribution keeps setup costs low while providing complete monitoring.

  • Wallbox and pedestal enclosures from 3.5kW to 22kW
  • Dual-gun configurations to maximize parking footprint
  • IP54 / IK10 impact-resistant housings
Future-Proof Engineering

Technical Roadmap & Architecture Matrix

How our factory builds power conversion systems that keep pace with changing EV battery voltages, from legacy 400V packs to modern 800V-1000V drivetrains.

Wide-Voltage Power Blocks

Moving away from traditional silicon IGBTs to third-generation Silicon Carbide (SiC) MOSFET rectifiers. Our current 30kW/40kW charging modules maintain high energy efficiency across 150VDC to 1000VDC.

  • Peak conversion efficiency exceeding 96.5%
  • Standby losses held below 10W per conversion cell
  • Stable power delivery for 400V passenger cars and 800V commercial trucks

Liquid Cooling & Megawatt Topologies

High charging currents beyond 350A generate excessive cable heat. Our split cabinets use closed-loop dielectric liquid cooling lines, allowing continuous 500A to 600A output without thick, heavy cables.

  • Thin, lightweight charging cables handle up to 600kW per gun
  • Low-noise centrifugal heat dissipation fans keep site noise under 65 dBA
  • Megawatt Charging System (MCS) integration for Class 8 freight

Vehicle-to-Grid (V2G) Bi-Directionality

Stationary vehicle batteries will serve as dynamic reserve power for local distribution grids. Our R&D team works directly with ISO 15118-20 frameworks to build functional bidirectional inverter stacks.

  • Reversible dual-active bridge (DAB) conversion modules
  • Sub-10ms switching between grid-draw and grid-inject modes
  • Utility-verified anti-islanding protection according to IEEE 1547
Certified Reliability

Multi-Regional Compliance & Certifications

Deploying charging stations worldwide requires local compliance. We hold ISO, CE, CB, and UL approvals to help international brands move quickly through technical tenders.

European Union & CE/CB Standards

Full conformance with the EU Alternative Fuels Infrastructure Regulation (AFIR), measuring standards via MID metering units, and product safety verified under IEC 61851-1, IEC 61851-23, and EN 62196 requirements.

North American UL Protocols

Engineered to UL 2202, UL 2594, and NFPA 70 National Electrical Code (NEC) articles. Compatible with CCS1 plug standards, early-stage NACS (SAE J3400) connector designs, and CTEP accuracy benchmarks.

Asia-Pacific, Latin America & Middle East

Pre-configured for local utility networks across Thailand, Brazil, UAE, and Australia. Designed to operate stably in hot, humid, or dusty environments with IP54 outdoor protection and operating tolerances from -30°C to +55°C.

ISO 9001 Certified Factory CE Mark Compliance CB Scheme Interoperability UL Listed Configurations CQC Product Quality
Technical Clarifications

B2B Procurement & Engineering Inquiries

Clear, direct answers regarding custom orders, testing procedures, software integration, and delivery schedules from our factory team.

What specific ODM and OEM customization levels does your factory offer?
Our factory handles modifications from sheet-metal branding and housing color coats to full circuit board design, UI adjustments, and connector layouts. We can assemble stations with specific cable lengths, customize internal component brands (such as Schneider contactors, Phoenix contact connectors, and Weidmüller terminals), build native OCPP profiles, and embed POS credit card terminals directly into the enclosure.
Which EV charging standards and physical connectors are supported?
Our equipment lines can be set up for GB/T (Chinese standard), Type 2 and CCS2 (European standard), CCS1 (North American standard), and CHAdeMO, along with emerging SAE J3400 (NACS) adapter and plug systems. Power architectures range from 3.5kW-22kW on AC inputs to 20kW-720kW on DC charging assemblies, allowing international distributors to fulfill tenders across different regions using one manufacturing partner.
Are your DC fast chargers and split systems OCPP compliant?
Yes. All models use OCPP 1.6-JSON protocols and can be upgraded to OCPP 2.0.1. The charging control units have been tested with major global backends and CSMS software, such as Driivz, AMPECO, ChargeLab, and Greenlots. Operators can connect stations directly to their own management software or use our proprietary cloud platform for over-the-air firmware updates (FOTA), user billing, and fault diagnostics.
What steps are taken to test and ensure reliability before export?
Every unit goes through a comprehensive multi-point testing process before shipping from our Kunshan facility. This includes full-load burn-in cycles running for at least 8 consecutive hours, insulation resistance checks, high-voltage dielectric tests, temperature rise measurements on the connector pins, and water-ingress testing. Certificates of Analysis (COA) and factory test records are included with every shipment.
When should an operator choose energy storage charging piles over standard DC cabinets?
Our 100kWh and 200kWh energy storage charging units are designed for sites where local electrical grid connections cannot support high peak loads, or where upgrading substation transformers is cost-prohibitive. Built-in Lithium Iron Phosphate (LFP) batteries store electricity during off-peak hours or charge directly from on-site solar systems, providing high-power DC fast charging without risking site overloads or triggering demand charges.
Hardware Catalog Part 2

Commercial AC Stations & Battery Integrated Piles

Complete product listings covering commercial digital displays, energy storage hubs, and dual-output AC charge points.

ODM 32-Inch Advertising DC Charging Pile 60-240kW

ODM 32-Inch Advertising DC Charging Pile 60–240kW | Integrated High-Traffic Solution

Configure Station
OEM 32-Inch Advertising DC Charging Pile 60-240kW

OEM 32-Inch Advertising DC Fast Pile 60-240kW | Dual Connector Public Enclosure

Configure Station
China AC EV Charger 3.5KW-21KW Dual Gun

3.5KW-21KW Dual Gun Wall-Mounted & Pedestal AC EV Charging Station

Configure Station
OEM China 60KW-400KW Integrated DC EV Charging Pile

OEM 60KW-400KW Integrated DC EV Charging Pile | High-Throughput Highway Cabinet

Configure Station
100KWh 200KWh Energy Storage Integrated Charging Pile

100KWh & 200KWh Energy Storage Integrated Charging Pile | Solar ESS Ready

Configure Station
CE Certified 60-360KW DC Fast Charger

CE Certified 60-360KW High-Speed DC Fast Charger | Operator-Grade Enclosure

Configure Station
3.5KW-22KW AC EV Charger Wall & Floor Mounted

3.5KW-22KW Commercial AC EV Charger | Pedestal & Wallbox Compact Form

Configure Station
OEM China EV-ONE AC Electric Vehicle Charger 3.5KW-22KW

EV-ONE AC Electric Vehicle Charger 3.5KW-22KW | Multi-Standard GB/T, CCS, NACS

Configure Station
HizonSun certificate enlarged view